ProLine
5,000 Watt DC to AC Inverter by Wagan Tech
®
11
www.wagan.com
WARNING: EXPLODING BATTERIES CAN SPRAY MOLTEN LEAD, HOT SULFURIC
ACID AND PLASTIC FRAGMENTS. BATTERIES THAT ARE CHARGING OR UNDER
HIGH DISCHARGE RATES CAN PRODUCE EXPLOSIVE HYDROGEN GAS INTO THE
SURROUNDING AREA. BE SAFE—FUSE THE BATTERY BANK AND MAKE SURE THE
BATTERY BANK LOCATION IS PROPERLY VENTILATED.
DC CABLE GAUGE
Minimize cable losses by using the thickest insulated stranded copper wire
available, and the shortest practical length. Refer to “Appendix A” at the rear of this
manual for suggested cable gauge.
INSTALLATION—CONNECTING AN INVERTER
GENERAL INFORMATION
This inverter must be mounted in a dry, cool and dust free environment.
If installation is on a wall or bulkhead, the inverter should be mounted horizontally.
Vertical mounting allows dust and objects to fall into inverter vents.
Loose connections will result in a severe voltage drop that can cause damage to
connectors, conductors and insulation and can cause sparking. Reverse polarity
connection will blow the fuses in the inverter and can permanently damage to the
inverter. Damage caused by reverse polarity will void the warranty.
NOTE: There are two sets of DC input terminals to ease cable connections and
reduce the need for larger gauge cables. No single terminal can carry more current
than described as follows:
Watts 2,500 5,000
Terminal Sets 1 2
All cables must be made of stranded, insulated copper wire. Measure the round trip
length of cable needed. Round trip is the distance from the negative battery bank
terminal to the inverter and back to the positive terminal of the battery bank. Use
a length of string and follow the route the cables will follow. Measure the length of
string and then determine the correct gauge cable required for the power level and
total distance. Appendix A has a table that relates cable length and gauge for your
inverter. Measure all terminal stud diameters that are to be connected to cables.
Obtain ring terminals that fit the cables and terminal studs. Be sure the ring terminals
can carry the current required.
GROUND TERMINAL WIRE REQUIREMENTS
Use a minimum of 6 gauge stranded wire for enclosure ground wire. Connect this
to the chassis of your vehicle or to the grounding system in your boat. In a city,
the ground wire can connect to a metal cold water pipe that goes underground. In
remote locations, the ground wire can be connected to an “earth ground”. This can